Open calculatorCalculation logic
Theoretical coverage S = 10 × VS / DFT (m²/L); volume V = area × coats / (S × η).
Worked example
For 100 m², one 40 µm coat, 50% VS and 70% efficiency: S = 12.5 m²/L and volume before reserve ≈ 11.43 L.
Before using the result
The efficiency combines application and handling losses. For a budget, confirm transfer efficiency, container residue, flushing losses, density and line data.